Calibrating a cheap hygrometer with table salt

Most inexpensive digital hygrometers drift by five to eight percent within a year. The classic fix costs almost nothing: a saturated salt solution holds the air above it at about 75 % relative humidity at room temperature.

What you need

Procedure

Put the cap and the hygrometer in the bag, seal it and leave it somewhere with a stable temperature for at least eight hours. Read the display without opening the bag. The difference from 75 % is your offset.

SensorReadingOffset
Hall71 %+4
Bedroom79 %−4
Workshop74 %+1

I repeat the test every spring; the offsets change less than I expected.